Model 6600-M4H: Military Pitot Static Tester with 3 Outputs
Lorem ipsum dolor sit amet, consectetur adipisicing elit, sed do eiusmod tempor incididunt ut labore et dolore magna aliqua. Ut enim ad minim veniam, quis nostrud exercitation ullamco laboris nisi ut aliquip ex ea commodo consequat. Duis aute irure dolor in reprehenderit in voluptate velit esse cillum dolore eu fugiat nulla pariatur. Excepteur sint occaecat cupidatat non proident, sunt in culpa qui officia deserunt mollit anim id est laborum.
- Specification
- Features
- Documents
Static Output
Pressure function
Range:
0.1 to 38 inHg
Resolution:
0.001 inHg
Accuracy:
±0.002 inHg
Units:
inHg, mbar
Altitude function
Range:
-4000 ft. to 100,000 ft.
Resolution:
1 foot
Accuracy:
± 2 ft. @ 0 ft.
± 6 ft. @ 35,000 ft.
± 12 ft. @ 50,000 ft.
± 50 ft. @ 80,000 ft.
Units:
Feet, Meters
Climb function
Range:
0 ft/min to ±50,000 ft/min
Resolution:
1 ft/min
Accuracy:
±1% of rate of climb
Units:
Feet/min, Meters/sec
Pitot Output
Pressure Function
Range:
0.1 to 100 inHg
Resolution:
0.001 inHg
Accuracy:
±0.003 inHg
Pt Units:
inHg, mbar, EPR
Qc Units:
inHg, mbar
Airspeed Function
Range:
0 to 1000 knots
Resolution:
0.1 knots
Accuracy:
± 0.5 knots @ 50 knots
< 0.25 knots above 100 knots
< 0.1 knots above 300 knots
Units:
knots, Mach, km/hr, mph
Rate of change:
0 to 800 knots/min
Mach Function
Range:
0.0 to 5.0 Mach
Resolution:
0.001 Mach
Accuracy:
±0.001 above 0.2 Mach
Differential Output (referenced to Static)
Secondary Static or Pitot Output
Range:
-30.0 to +30.0 inHg
Resolution:
0.001 inHg
Accuracy:
±0.002 inHg
Units:
inHg, mbar, Dfin, Dfmb, feet, mtrs, knots, kmph
Power Requirement
90-260 VAC, 47-440 Hz ; 350 VA
External Interfaces
RS232 ; IEEE-488 & Encoder optional
Dimensions & weights
Main unit:
22” x 14” x 9” / 40 lbs
Remote unit:
7” x 8” x 2” / 1 lb.
Environmental Specs
Operating temp.
-40 to 50°C
Storage temp.:
-40 to 75°C
Humidity:
5 to 100%
Features
Three Outputs In addition to the Primary Static and Pitot outputs, a third output is provided. This output can be used as a secondary static, a differential static or secondary pitot. This output allows the user to create a second altitude (in feet or mtrs), a second absolute pressure (in inHg or mbar), a differential pressure for simulating AOA (in Diff.inHg or Diff mbar) or a differential pressure for generating a second airspeed (in knots or kmph) to simulate AOS. When the third output is not used, the tester operates exactly like our 2-output tester (Model 6300). |
RVSM compliant The high accuracy of the tester and NIST-traceable calibration make the tester fully RVSM-compliant and suitable for use on all RVSM-compliant aircraft. |
Calibration period: 1 year |
Automated operation Simply enter the target set-points for the three outputs and the unit automatically achieves the targets, ramping at the programmed rates. Control at the set-point is stable within ± 1 foot, ± 0.1 knot or ± 0.001 inHg |
Programmable limits User-programmable limits for altitude, airspeed, differential pressure, Mach and VSI provide protection to the aircraft. |
“Jog” and “Hold” features Set-points can be “jogged” up or down in small increments. Ramping to a set-point can be put on “hold” and controlled at the current measured value. |
“Ground” feature Brings Pitot and Static outputs to ambient “ground” pressure after completing a test. |
“Profiles” feature A profile of set-points can be downloaded from a PC, allowing the user to step through the set-points using a single key. Each profile can have up to 50 set-points and 12 profiles can be stored in the unit. |
Leak checks Leak-checks can be performed independently on any of the three outputs. The display of “instant” leak rates provides immediate feedback to the user. |
Pressure & Vacuum source Built-in high-capacity dual vacuum pumps and pressure pump provide the pressure and vacuum source for the unit. |
Remote unit The Remote unit is the operator interface for the tester. All valid parameters of all three outputs are clearly displayed simultaneously on a single screen on the remote. |
Manual Vent The tester includes precision metering valves to enable manual venting of all three outputs, in the event of power-loss |
Applications
Ideal tester for use with aircraft equipped with “smart probes” that have the ability to sense AOA and/ or AOS. |
Works identically to the 6600 but can simulate higher altitudes and airspeeds. Also, this tester has a wider operating temperature. Therefore this tester is ideal for military aircraft equipped with “smart probes” |
Leak-checks and Air-data-system accuracy-checks on all RVSM aircraft (military and commercial) including aircraft with “smart probes”. The tester can be used either in 3-output mode or 2-output mode. In 2-output mode this tester operates exactly like our Model 6300-M3. |
When the 6600-M4H is used with the OSM (Output Switching Module) it is possible to completely automate leak checks, which can be performed either individually on each port of the aircraft probes, or simultaneously on all ports. Using the OSM makes it easy to isolate leaks and connection of the hoses and adapters to the aircraft is greatly simplified. |