Model 6500/6500-HA: Automated Air Data Test Set

Model 6500/6500-HA: Automated Air Data Test Set

NSN: 4920 01 375 7472 (Model 6500)

The 6500 & 6500-HA (High-Accuracy) Air Data Test Sets require only a pressure source and a vacuum source and are extremely simple to use. They can be used to test and calibrate altimeters, airspeed / Mach indicators, Climb indicators, Flight data recorders, Air data computers, and EPR indicators. The high accuracy of these units meets all RVSM requirements. Also, they need to be calibrated only once a year. The use of “Profiles” makes it possible for the operator to run through a test using only a single key on the front panel keypad of these units.

Share this product!

  • Specifications
  • Features
  • Documents
  • Ordering Information

Description

Static Output

6500

6500-HA

Pressure function

Range:

0.1 to 42 inHg

0.1 to 38 inHg

Resolution:

0.001 inHg

0.0001 inHg

Accuracy:

±0.002 inHg

±0.001 inHg

Units:

inHg, mbar

inHg, mbar

Altitude function

Range:

-4000 ft. to 100,000 ft.

-4000 ft. to 100,000 ft.

Resolution:

1 foot

1 foot

Accuracy:

± 2 ft. @ 0 ft.
± 6 ft. @ 35,000 ft.
± 12 ft. @ 50,000 ft.
± 50 ft. @ 80,000 ft.

± 1 ft. @ 0 ft.
± 3 ft. @ 35,000 ft.
± 6 ft. @ 50,000 ft.
± 25 ft. @ 80,000 ft.

Units:

Feet, Meters

Feet, Meters

Climb function

Range:

0 ft/min to ±50,000 ft/min

0 ft/min to ±50,000 ft/min

Resolution:

1 ft/min

1 ft/min

Accuracy:

±1% of rate of climb

±1% of rate of climb

Units:

Feet/min, Meters/sec

Feet/min, Meters/sec

Pitot Output

Pressure Function

Range:

0.1 to 110 inHg

0.1 to 100 inHg

Resolution:

0.001 inHg

0.0001 inHg

Accuracy:

±0.003 inHg

±0.002 inHg

Pt Units:

inHg, mbar, EPR

inHg, mbar, EPR

Qc Units:

inHg, mbar

inHg, mbar

Airspeed Function

Range:

0 to 1100 knots

0 to 1100 knots

Resolution:

0.1 knots

0.1 knots

Accuracy:

± 1.5 knots @ 20 knots
± 0.5 knots @ 50 knots
0.25 knots above 100 knots
0.1 knots above 300 knots

± 1.0 knots @ 20 knots
± 0.2 knots @ 100 knots
± 0.03 knots @ 500 knots
± 0.01 knots @ 1000 knots

Units:

knots, Mach, km/hr, mph

knots, Mach, km/hr, mph

Rate of change:

0 to 500 knots/min

0 to 500 knots/min

Mach Function

Range:

0.0 to 5.0 Mach

0.0 to 10.0 Mach

Resolution:

0.001 Mach

0.001 Mach

Accuracy:

±0.001 above 0.2 Mach

±0.001 above 0.2 Mach

Power Requirement

90-260 VAC, 47-440 Hz ; 200 VA

External Interfaces

RS232 and IEEE-488; Remote unit optional

Dimensions & weights

19-inch rack-mount kit optional: 6.5” (h) x 15.5” (w) x 17.0” (d) / 20 lbs

Environmental Specs

Operating temp.

0 to 50°C

0 to 50°C

Storage temp.:

-25 to 75°C

-25 to 75°C

Humidity:

5 to 95% non-condensing

5 to 95% non-condensing

Features

RVSM compliant
6500: The high accuracy of the tester and NIST-traceable calibration make the tester fully RVSM-compliant.
6500-HA: The very high accuracy of the tester and NIST-traceable calibration make the tester fully RVSM-compliant.
Calibration period
6500/6500-HA: 1 year
Automated operation
6500: Simply enter the target set-points for altitude and airspeed and the unit automatically achieves the targets, ramping at the programmed rates. Control at the set-point is stable within ± 1 foot, ± 0.1 knot or ±0.001 inHg.
6500-HA: Simply enter the target set-points for altitude and airspeed and the unit automatically achieves the targets, ramping at the programmed rates. Control at the set-point is stable within ± 1 foot, ± 0.1 knot or ± 0.0002 inHg
Programmable limits
6500/6500-HA: User-programmable limits for altitude, airspeed, Mach and VSI provide protection to the aircraft.
“Jog” and “Hold” features
6500/6500-HA: Set-points can be “jogged” up or down in small increments. Ramping to a set-point can be put on “hold” and controlled at the current measured value.
“Ground” feature
6500-HA: Brings Pitot and Static outputs to ambient “ground” pressure after completing a test.
“Profiles” feature
6500/6500-HA: A profile of set-points can be downloaded from a PC, allowing the user to step through the set-points using a single key. Each profile can have up to 50 set-points and 20 profiles can be stored in the unit.
Leak checks
6500/6500-HA: Pitot and Static leak-checks can be performed either independently or simultaneously. Three leak-timers can be programmed to perform timed leaks between 1 to 20 minutes. The display of “instant” leak rates provides immediate feedback to the user.
Pressure & Vacuum requirement
6500/6500-HA: External pressure (Dry Air only) and vacuum supplies are required. The PVS is ideally suited for providing these supplies.
Local display and keypad
6500/6500-HA: The local display and keypad are the operator interface for the tester. All valid parameters, including altitude, climb and airspeed, are clearly displayed simultaneously on a single screen on the local display.

Applications

6500/6500-HA: Ideal tester for use in an instrument-shop for testing and calibrating ADC’s, altimeters, airspeed indicators, VSI’s, cabin pressure controllers, FDR’s and other air-data instruments.
6500/6500-HA: Can be rack-mounted in ATE systems
6500-HA: The very high accuracy of this tester makes it suitable for use as a convenient Transfer Standard.

System

Part Number
Description
131-0350
Model 6500 Automated Air Data Bench Test Set

Accessories

Part Number
Description
131-0168
Pressure/Vacuum source for use with the Model 6500