Model 6300: RVSM Automated Pitot Static Tester (Most Versatile 2-Ch Tester)
The Model 6300 is a versatile 2-channel RVSM Pitot Static Tester targeted for General Aviation; all Business Jets and Commercial Aircraft. It is used to perform leak-checks and accuracy checks on the Pitot Static systems of RVSM aircraft up to 690 knots & 60,000 ft. Accuracy checks are typically performed on altimeters, airspeed indicators and VSI’s. The Model 6300 is equipped with a Remote unit with large keypad and display, a removable 8-hour battery (optional), wide operating temperature (optional), and “profiles” to accelerate testing. Calibration is required only once a year. The 6300 can be controlled by an iPad or other tablets.
The Model 6300 is approved for Boeing, Airbus, and most OEMs.
- Specifications
- Features
- Documents
- Ordering Information
Description
Static Output
Pressure function
Range:
1 to 32 inHg
Resolution:
0.001 inHg
Accuracy:
±0.002 inHg
Units:
inHG, mbar, psi, mmHG, kpa
Pressure Rate
Range:
0 to 30 inHg/min
Resolution:
0.001 inHg/min
Accuracy:
±1% of rate
Units:
pressure-units/min
Altitude function
Range:
-2000 ft. to 60,000 ft.
Resolution:
1 foot
Accuracy:
± 3 ft. @ 0 ft.
± 4 ft. @ 10,000 ft.
± 6 ft. @ 20,000 ft.
± 9 ft. @ 35,000 ft.
± 18 ft. @ 50,000 ft.
Units:
Feet, Meters
Climb function
Range:
0 ft/min to ±15,000 ft/min
Resolution:
1 ft/min
Accuracy:
±1% of rate of climb
Units:
Feet/min, Meters/sec
Pitot Output
Pressure Function
Range:
0 to 30 inHg
Resolution:
0.001 inHg
Accuracy:
±0.003 inHg
Pt Units:
inHg, mbar, psi, mmHg, kpa, EPR
Qc Units:
inHg, mbar, psi, mmHg, kpa
Pressure Rate
Range:
0 to 30 inHg/min
Resolution:
0.001 inHg/min
Accuracy:
±1% of rate
Units:
pressure-units/min (EPR in inHg/min)
Airspeed Function
Range:
0 to 690 knots
Resolution:
0.1 knots
Accuracy:
± 1.0 knots @ 20 knots
± 0.3 knots @ 50 knots
± 0.2 knots @ 100 knots
± 0.1 knots @ 200 knots
± 0.04 knots @ 500 knots
Units:
knots, Mach, km/hr, mph
Rate of change:
0 to 500 knots/min
Airspeed Rate
Range:
0 to 500 knots/min
Resolution:
0.1 knots/min (0.01 km/hr/sec)
Accuracy:
±2% of rate
Units:
knots/min, km/hr/sec, mph/min
Mach Function
Range:
0.0 to 3.0 Mach
Resolution:
0.001 Mach
Accuracy:
±0.001 above 0.2 Mach
Power Requirement
90-260 VAC, 47-440 Hz, 100 W (200 W with heaters)
Optional Removable Battery: 6 to 8 hours of operation
External Interfaces
WiFi, RS232 Serial ; Encoder optional
Dimensions & weights
Main unit:
22” x 14” x 9” / 34 lbs
Remote unit:
6” x 6” x 1” / 1.8 lb.
Environmental Specs
Operating temp.
0°C to 50°C, –40°C to 50°C (optional)
Storage temp.:
–40°C to 75°C
Humidity:
5 to 100%
Features
WiFi-enabled |
RVSM & Automated operation Simply enter the target set-points for altitude and airspeed and the unit automatically achieves the targets, ramping at the programmed rates. Control at the set-point is stable within ± 1 foot and ± 0.1 knot. This RVSM tester’s low price makes it very affordable |
Calibration period: 1 year |
Programmable limits User-programmable limits for altitude, airspeed, Mach, VSI and airspeed-rate provide protection to the aircraft. |
Negative-airspeed protection An internal differential-pressure relief valve provides protection against negative airspeed. |
Removable Battery (Optional) The removable battery allows for 6 to 8 hours of continuous operation. Re-charge time is only 8 hours. |
Low-temperature operation (optional) With optional internal heaters, the unit can be operated down to -40°C |
“Jog” and “Hold” features Set-points can be “jogged” up or down in small increments. Ramping to a set-point can be put on “hold” and controlled at the current measured value. |
“Ground” feature Brings Pitot and Static outputs to ambient “ground” pressure after completing a test. Ambient pressure is constantly monitored. |
“Profiles” feature A profile of set-points can be downloaded from a PC, allowing the user to step through the set-points using a single key. Each profile can have up to 50 set-points and 15 profiles can be stored in the unit. |
Leak checks Pitot and Static leak-checks can be performed either independently or simultaneously. Three leak-timers can be programmed to perform timed leaks between 1 to 20 minutes. The display of “instant” leak rates provides immediate feedback to the user. |
Pressure & Vacuum source Built-in diaphragm pumps provide the pressure and vacuum source for the unit. |
Remote unit The Remote unit is the operator interface for the tester. It features a sunlight-readable 5.8” color display, a back-lit keypad and a touch-screen (which can be disabled). All operations are performed from a single screen which displays all pertinent parameters. |
Manual Vent Valves On loss of power, the unit maintains pressure. The unit can be manually vented to “Ground” at a controlled rate using precision metering valves. Applications |
Applications
Leak-checks and accuracy-checks on Commercial, Business and Military aircraft |
Leak-checks and accuracy-checks on Helicopters and UAVs |
Ideal for heavy-maintenance and line-maintenance by commercial airlines |
System
Accessories