Model 6600:Automated Pitot Static Tester with 3 Outputs

Model 6600:Automated Pitot Static Tester with 3 Outputs

Specifications

Static Output

Pressure function

range:
resolution:
accuracy:
units:
0.1 to 42 inHg
0.001 inHg
±0.002 inHg
inHg, mbar

Altitude function

range:
resolution:
accuracy:
-4000 ft. to 60,000 ft.
1 foot
± 2 ft. @ 0 ft.
± 6 ft. @ 35,000 ft.
± 12 ft. @ 50,000 ft.
units: feet, meters

Climb function

range:
resolution:
accuracy:
units:
0 ft/min to ±25,000 ft/min
1 ft/min
±1% of rate of climb
feet/min, meters/sec

Pitot Output

Pressure function

range:
resolution:
accuracy:
Pt units:
Qc units:
0.1 to 60 inHg
0.001 inHg
±0.003 inHg
inHg, mbar, EPR
inHg, mbar

Airspeed function

range:
resolution:
accuracy:
0 to 650 knots
0.1 knots
± 0.5 knots @ 50 knots
± 0.25 knots @ 100 knots
± 0.05 knots @ 650 knots
units: knots, km/hr, mph, Mach
Rate of change: 0 to 500 knots/min

Mach function

range:
resolution:
accuracy:
0.0 to 3.0 Mach
0.001 Mach
±0.001 above 0.2 Mach

Differential Output (referenced to Static)
(Secondary Static or Pitot Output)

range:
resolution:
accuracy:
-30.0 to +30.0 inHg
0.001 inHg
±0.002 inHg
inHg, mbar, Dfin, Dfmb,
Units: feet, mtrs, knots, kmph

Power requirement

90-260 VAC, 47-440 Hz ; 200 VA

External Interface

RS232 ; IEEE-488 & Encoder optional

Dimensions & weights

Main unit:
Remote unit:
22” x 14” x 9” / 40 lbs
7” x 8” x 2” / 1 lb.

Environmental specs

Operating temp.
Storage temp.
Humidity:
0 to 50°C
-25 to 75°C
5 to 100%

Features

Three Outputs In addition to the Primary Static and Pitot outputs, a third output is provided. This output can be used as a secondary static, a differential static or secondary pitot. This output allows the user to create a second altitude (in feet or mtrs), a second absolute pressure (in inHg or mbar), a differential pressure for simulating AOA (in Diff.inHg or Diff mbar) or a differential pressure for generating a second airspeed (in knots or kmph) to simulate AOS.
When the third output is not used, the tester operates exactly like our 2-output tester (Model 6300)

RVSM compliantThe high accuracy of the tester and NIST-traceable calibration make the tester fully RVSM-compliant and suitable for use on all RVSM-compliant aircraft.

Calibration period: 1 year

Automated operation Simply enter the target set-points for the three outputs and the unit automatically achieves the targets, ramping at the programmed rates. Control at the set-point is stable within ± 1 foot, ± 0.1 knot or ± 0.001 inHg

Programmable limits User-programmable limits for altitude, airspeed, differential pressure, Mach and VSI provide protection to the aircraft.

“Jog” and “Hold” features Set-points can be “jogged” up or down in small increments. Ramping to a set-point can be put on “hold” and controlled at the current measured value.

“Ground” featureBrings Pitot and Static outputs to ambient “ground” pressure after completing a test.

“Profiles” featureA profile of set-points can be downloaded from a PC, allowing the user to step through the set-points using a single key. Each profile can have up to 50 set-points and 12 profiles can be stored in the unit.

Leak checks Leak-checks can be performed independently on any of the three outputs. The display of “instant” leak rates provides immediate feedback to the user.

Pressure & Vacuum sourceBuilt-in high-capacity dual vacuum pumps and pressure pump provide the pressure and vacuum source for the unit.

Remote unit The Remote unit is the operator interface for the tester. All valid parameters of all three outputs are clearly displayed simultaneously on a single screen on the remote.

Manual VentThe tester includes precision metering valves to enable manual venting of all three outputs, in the event of power-loss

Applications

  • Ideal tester for use with aircraft equipped with “smart probes” that have the ability to sense AOA and/ or AOS.
  • Leak-checks and Air-data-system accuracy-checks on all RVSM aircraft including aircraft with “smart probes”. The tester can be used either in 3-output mode or 2-output mode. In 2-output mode this tester operates exactly like our Model 6300.
  • When the 6600 is used with the OSM (Output Switching Module) it is possible to completely automate leak checks, which can be performed either individually on each port of the aircraft probes, or simultaneously on all ports. Using the OSM makes it easy to isolate leaks and connection of the hoses and adapters to the aircraft is greatly simplified.